Heat Load Calculator

Calculate precise heating requirements based on building parameters and insulation

Professional Heat Load Calculator

Precise heating system sizing based on building parameters

Building Details

Technical Parameters

Understanding Heat Load Calculations

Professional methodology for accurate heating system sizing

Building Envelope

Wall, roof, and foundation heat losses based on insulation levels

Windows & Doors

Glazing performance and thermal bridging effects

Climate Factors

Local weather conditions and temperature differences

Ventilation

Air changes and infiltration heat losses

Why Accurate Heat Load Matters

Professional sizing prevents costly mistakes and ensures optimal performance

Right Size System

Avoid oversized or undersized heating equipment that leads to inefficiency and discomfort

Cost Savings

Properly sized systems operate more efficiently, reducing energy bills and maintenance costs

🏠

Comfort

Consistent temperatures and optimal humidity levels throughout your building

  1. 1

    Entrez dimensions bâtiment

    Mesurer superficie chauffée (m²) et hauteur plafond. Exclure espaces non chauffés (garages, greniers). Volume (superficie × hauteur) détermine air nécessitant chauffage. Plafonds plus hauts = volume supérieur = plus charge chauffage.

  2. 2

    Sélectionnez zone climatique

    Choisir zone ASHRAE (1-7) ou température design hiver. Cela représente température extérieure minimale attendue. Climats froids (zones 6-7) nécessitent capacité chauffage significativement supérieure climats modérés (zones 3-4).

  3. 3

    Évaluez qualité isolation

    Sélectionner niveau isolation: mauvaise (R-10 combles, R-5 murs), moyenne (R-25 combles, R-13 murs), bonne (R-38 combles, R-19 murs), excellente (R-50 combles, R-25 murs). Meilleure isolation = charge chauffage moindre = système plus petit nécessaire.

  4. 4

    Calculez perte chaleur fenêtres

    Entrer superficie total fenêtres et type: simple vitrage (U-5.0), double (U-2.8), double low-E (U-1.7), triple (U-1.0). Fenêtres représentent 25-35% perte chaleur. Plus/pires fenêtres = charge chauffage supérieure.

  5. 5

    Évaluez infiltration air

    Estimer étanchéité air: étanche (test porte soufflante <3 ACH50), moyenne (3-7 ACH50), lâche (>7 ACH50). Maisons plus anciennes typiquement lâches. Fuites air augmentent charge chauffage 10-30%. Colmatage réduit charge et améliore confort.

  6. 6

    Calculez charge chauffage totale

    Calculatrice somme perte chaleur: murs + toit + fenêtres + portes + sol + infiltration air. Résultat kW ou BTU/h capacité chauffage requise. Typique: 25-60 BTU/pi² selon isolation et climat. Utiliser dimensionner système chauffage approprié.

  7. 7

    Optimisez charge chauffage

    Réduire charge avant remplacer système: 1) Ajouter isolation combles (réduit charge 15-25%), 2) Améliorer fenêtres (10-20%), 3) Colmater air (10-20%), 4) Isoler sous-sol (10-15%). Charge moindre = système plus petit moins cher, factures moindres.